QC2.0 Interface Module
Applications Information
HM100 is a low-cost USB high-voltage dedicated Shunt Regulator
charging port interface IC for the Quick Charge The internal shunt regulator clamps the BYPASS
2.0 specification. It incorporates all necessary pin at 6 V when current is provided through an
functions to add Quick Charge 2.0 c apability to external resistor (RBP in Figure 1). This
standard Adaptors, Car-chargers, and Portable facilitates powering of HM100 externally over the
Battery Packs.
wide power supply output voltage range of 5 V
HM100 also supports other solutions with to 20 V. Recommended values are RBP = 4.7
traditional feedback schemes like opto-coupler and CBP = 220 nF.
and secondary reference regulator SE431 as
depicted in Figure 1.
BYPASS Pin Undervoltage
The BYPASS pin undervoltage circuitry resets
the HM100 when the BYPASS pin voltage drops
below 3.9 V . Once the BYPASS pin voltage
drops below 3.9 V it must rise back to 4 V to
enable correct operation.
Reference Input
Resister RREF at the REFERENCE pin is
connected to an internal band gap reference and
provides an accurate reference current for
internal timing circuits. The recommended value
Figure 1. HM100 with Traditional Output Regulation (CV Only).
is RREF = 127 kΩ.
Quick Charge 2.0 Interface
HM100 supports the full output voltage range of At power-up HM100 turns on s witch N5 (see
Quick Charge 2.0 Class A (5 V, 9 V, or 12 V) or Figure 3) in 20 ms or less after the BYPASS pin
Class B (5 V, 9 V , 12 V , or 20 V ). It voltage has reached 4 V. Switch N4 and output
automatically detects either Quick Charge 2.0 switches N1 to N3 remain off. This sets the
capable powered devices (PD) or legacy PDs default 5 V output voltage level. With D+ and D-
compliant with the USB Battery Charging short-circuited the normal handshake between
Specification revision 1.2 a nd only enables the AC-DC adapter (DCP) and powered devices
output voltage adjustment accordingly.
(PD) as described in the USB Battery Charging
Specification 1.2 c an commence. After switch
N5 has been turned on HM100 starts monitoring
the voltage level at D+. If it continuously stays
At USB cable disconnect the voltage level at D+