DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

M220Z1-L10 データシートの表示(PDF) - Unspecified

部品番号
コンポーネント説明
メーカー
M220Z1-L10
ETC
Unspecified ETC
M220Z1-L10 Datasheet PDF : 26 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
Issued Date: Jan. 06, 2009
Model No.: M220Z1-L10
Approval
6.2 POWER ON/OFF SEQUENCE
To prevent a latch-up or DC operation of LCD module, the power on/off sequence should be as the
diagram below.
- Power Supply 0V
for LCD, Vcc
Power On
90%
10%
t1
t2
Power Off Restart
90%
t7
10%
10%
t4
t3
- Interface Signal
(LVDS Signal of 0V
Transmitter), VI
- Power for Lamp
Valid Data
t5
t6
50%
50%
OFF
ON
OFF
Timing Specifications:
0.5< t1 10 msec
0 < t2 50 msec
0 < t3 50 msec
t4 500 msec
t5 450 msec
t6 90 msec
5 t7 100 msec
Note
(1) The supply voltage of the external system for the module input should be the same as the definition of Vcc.
(2) Apply the lamp voltage within the LCD operation range. When the backlight turns on before the LCD
operation of the LCD turns off before the backlight turns off, the display may momentarily become abnormal
screen.
(3) In case of VCC = off level, please keep the level of input signals on the low or keep a high impedance.
(4) T4 should be measured after the module has been fully discharged between power off and on period.
(5) Interface signal shall not be kept at high impedance when the power is on.
(6) The company will not guarantee or compensate for the product damage caused by not following the Power
Sequence.