DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX822LUS-T(1999) データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
MAX822LUS-T Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
4-Pin µP Voltage Monitors with Pin-Selectable
Power-On Reset Timeout Delay
ABSOLUTE MAXIMUM RATINGS
Terminal Voltage (with respect to GND)
VCC ......................................................................-0.3V to 6.0V
All Other Inputs.......................................-0.3V to (VCC + 0.3V)
Input Current, VCC, SRT......................................................20mA
Output Current, RESET or RESET .......................................20mA
Continuous Power Dissipation (TA = +70°C)
SOT143-4 (derate 4mW/°C above +70°C)...................320mW
Operating Temperature Range .........................-40°C to +125°C
Storage Temperature Range .............................-65°C to +160°C
Lead Temperature (soldering, 10sec) .............................+300°C
Stresses beyond those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. These are stress ratings only, and functional
operation of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not implied. Exposure to
absolute maximum rating conditions for extended periods may affect device reliability.
ELECTRICAL CHARACTERISTICS
(VCC = full range, TA = -40°C to +125°C, unless otherwise noted. Typical values are at TA = +25°C.)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
VCC Range
Supply Current
Reset Threshold (Note 1)
Reset Threshold Tempco
TA = 0°C to +70°C
TA = -40°C to +85°C
MAX82_L/M/P,
TA = +25°C
ICC
VCC = 5.5V, IOUT = 0
MAX82_R/S/T/U,
TA = TMIN to TMAX
TA = +25°C
VCC = 5.5V, IOUT = 0 TA = TMIN to TMAX
MAX82_L
TA = +25°C
TA = -40°C to +125°C
MAX82_M
TA = +25°C
TA = -40°C to +125°C
MAX82_P
TA = +25°C
TA = -40°C to +125°C
VTH MAX82_T
TA = +25°C
TA = -40°C to +125°C
MAX82_S
TA = +25°C
TA = -40°C to +125°C
MAX82_U
TA = +25°C
TA = -40°C to +125°C
MAX82_R
TA = +25°C
TA = -40°C to +125°C
1.0
5.5
V
1.2
5.5
2.5
7.0
12
µA
1.8
5.5
9
4.56 4.63 4.70
4.50
4.75
4.31 4.38 4.45
4.25
4.50
3.97 4.00 4.04
3.91
4.09
3.04 3.08 3.11
V
3.00
3.15
2.89 2.93 2.96
2.85
3.00
2.74 2.78 2.81
2.70
2.85
2.59 2.63 2.66
2.55
2.70
30
ppm/°C
VCC to Reset Delay (Note 1)
VCC falling at 1mV/µs
SRT = GND
50
µs
0.5
0.8
1
Reset Active Timeout Period
tRP
SRT = VCC
SRT = unconnected
20
32
40
ms
100
160
200
SRT Input Current (Note 2)
SRT = GND
RESET = low for MAX821,
RESET = high for MAX822
SRT = VCC
SRT = unconnected
-100
-1
100
µA
1
SRT Input Threshold
VIL
VIH
VOPEN
RESET = low for MAX821,
RESET = high for MAX822
0.07VCC
0.9VCC
V
0.5VCC
2 _______________________________________________________________________________________