MPU/MDU150 SERIES
MPU150 INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Continuous input range.
85
264
VAC
AC input.
47
63
Hz
After last AC line peak at 150 watts.
MPU150-4350 17.5
mS
All other models
20
85 VAC at full rated load.
3.0
ARMS
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
35
APK
Per EN61000-3-2.
0.95
W/VA
Switching frequency of main output transformer.
100
120
Switching frequency of secondary transformer.
65
90
kHz
Switching frequency of Power Factor Correction circuit.
60
MDU150 INPUT SPECIFICATIONS
PARAMETER
Input Voltage - DC
Brown Out Protection
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Operating Frequency
CONDITIONS/DESCRIPTION
Continuous input range.
Lowest DC input voltage that regulation is maintained with full rated loads.
At 150 watts, over DC input range.
36 VDC at full rated load.
Non-user serviceable internally located AC input line fuse.
Vin = 72 VDC.
Switching frequency of main output transformer.
Switching frequency of secondary transformer.
MIN
NOM
MAX
UNITS
36
75
VDC
34
VDC
20
mS
6.4
ARMS
35
APK
100
kHz
70
OUTPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
Efficiency
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Minimum Loads
Minimum load required to maintain regulation on
V2 at maximum load.
MPU150-3300, V1
All other models, V1
Ripple and Noise
Full load, 20MHz bandwidth.
Output Power
With 300 LFM forced air cooling. (NOTE 1)
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on.
Regulation
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Turn-on Delay
Time required for initial output voltage stabilization.
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
NOTES: 1) This product is not rated for convection applications.
INTERFACE SIGNALS AND INTERNAL PROTECTION
MIN
NOM
MAX
65
75
4
3
See Model Selection Charts
150
0
See Model Selection Charts
500
2
20
UNITS
%
A
Watts
%
µS
Sec
mS
2

Share Link: 