MPU150/MDU150 SERIES
DC INPUT MODEL SELECTION CHART – 150W WITH 300 LFM FORCED AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
MDU150-3300
MDU150-4000
MDU150-4530
OUTPUT
VOLTAGE
+3.3V
+5V
+12V
+5V
+12V
12V
5V
+5V
+3.3V
12V
12V
ADJUSTMENT
RANGE
3.15V to 3.80V
5.0V to 5.5V
N/A
5.0V to 5.5V
10.8V to 13.2V
10.8V to 13.2V
5.0V to 5.5V
5.0V to 5.5V
3.15V to 3.60V
10.8V to 13.2V
10.8V to 13.2V
OUTPUT
CURRENT (NOTE 1)
35A
20A
2A
30A (Note 3)
8A
3A
2A
30A (Note 3)
15A (Note 3)
3A (Note 4)
3A (Note 4)
LINE
REGULATION
0.6%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.4%
0.6%
0.4%
0.4%
LOAD
REGULATION
1.5%
3%
3%
1%
1%
1%
1%
1%
1.5%
7%
7%
RIPPLE & NOISE
%Pk-Pk (NOTE 2)
1.5%
1%
1%
1%
1%
1%
1%
1%
1.5%
1%
1%
INITIAL SETTING
ACCURACY
3.28V to 3.32V
4.98V to 5.02V
11.76V to 12.24V
4.98V to 5.02V
11.94V to 12.06V
11.94V to 12.06V
4.98V to 5.02V
4.98V to 5.02V
3.28V to 3.32V
11.94V to 12.06V
11.94V to 12.06V
MPU150 INPUT SPECIFICATIONS
PARAMETER
Input Voltage - AC
Input Frequency
Hold-up Time
Input Current
Input Protection
Inrush Surge Current
Power Factor
Operating Frequency
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Continuous input range.
85
264
VAC
AC input.
47
63
Hz
After last AC line peak at 150 watts.
MPU150-4350
17.5
mS
All other models
20
85 VAC at full rated load.
MPU150
3.0
ARMS
Non-user serviceable internally located AC input line fuse.
Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C.
35
APK
Per EN61000-3-2.
0.95
W/VA
Switching frequency of main output transformer.
100
120
Switching frequency of secondary transformer.
65
90
kHz
Switching frequency of Power Factor Correction circuit.
60
MDU150 INPUT SPECIFICATIONS
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Input Voltage - DC
Continuous input range.
36
75
Brown Out Protection
Lowest DC input voltage that regulation is maintained with full rated loads.
34
Hold-up Time
At 150 watts, over DC input range.
20
Input Current
36 VDC at full rated load.
6.4
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Vin = 72 VDC.
35
Operating Frequency
Switching frequency of main output transformer.
100
Switching frequency of secondary transformer.
70
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air.
3) Total current between V1 and V2 is 30A, maximum rating.
2) Maximum peak to peak noise expressed as a percentage of output voltage, 20MHz bandwidth. 4) Total current between V3 and V4 is 5A, maximum rating.
UNITS
VDC
VDC
mS
ARMS
APK
kHz
2