MPU150-4530(1999) データシートの表示(PDF) - Power-One Inc.

部品番号
コンポーネント説明
メーカー
MPU150-4530
(Rev.:1999)
Power-One
Power-One Inc. Power-One
MPU150-4530 Datasheet PDF : 4 Pages
1 2 3 4
®
MPU/MDU150 SERIES
PARAMETER
Overvoltage Protection
CONDITIONS/DESCRIPTION
Latch style overvoltage protection. Available on
V1, V2, all models, and V3 on all models except
MPU150-3300.
MPU150-4350.
MIN
3.3V output, V1 4.1
3.3V output, V2 3.8
5V output, V1, V2 6.0
12V output, V2 (Note 1) 14
3.3V output, V1 4.3
NOM
MAX
4.65
4.2
6.4
16
4.65
Overload Protection
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset.
Output Good
Input Power Fail Warning
TTL compatible signal available for V1. Signal is high when
output is within 5% of nominal. Signal shall remain low for 20
milliseconds following loss of Output Good.
3.3V 3.16
5V 4.75
TTL compatible logic signal. Time before regulation dropout due to loss of input
5
power. May be used as independent PSOK signal in redundant applications.
Current Share
Accuracy of shared current with up to 6 parallel units. Single wire current share
10
on V1 and V2 with return via -Sense return.
Remote Sense
Available on V1 and V2. Total voltage compensation for cable losses with
250
respect to the main output.
Inhibit
Output voltage is inhibited by application of an external high (5V) signal.
NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V.
UNITS
V
V
mS
%
mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
FCC CFR title 47 Part 15 Sub-Part J - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
ENVIRONMENTAL SPECIFICATIONS
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
MIN
MPU150
MDU150
Line to Line
Line to Ground
2600
1544
B
B
8
10
±2
1
2
MPU150 at 264 VAC
MDU150 at 72 VDC
NOM
MAX
UNITS
Approved
VDC
Class
kV
V/M
kV
kV
10
M
1250
µA
100
MIN
At 100% load 0
At 50% load 0
-55
5
NOM
±0.02
MAX
10k
40k
50
70
85
±0.05
95
20
6
UNITS
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
GPK
GRMS
OPTIONS
DESCRIPTION
Metric Mounting
NOTES
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts.
SIZE IMPACT
8.00" x 4.20" x 1.50"
(203.2mm x 106.7mm x 38.1mm)
3