MPU150/MDU150 SERIES
OUTPUT SPECIFICATIONS
PARAMETER
Efficiency
Minimum Load, V1
Minimum Load, V3
Ripple and Noise
Output Power
Overshoot / Undershoot
Regulation
Transient Response
Turn-on Delay
Turn-on Rise Time
CONDITIONS/DESCRIPTION
Full Rated Load, 110 VAC. Varies with distribution of loads among outputs.
Minimum load required to maintain regulation on
V2 at maximum load.
MPU150-3300, V1
All other models, V1
Minimum load required to maintain regulation on
V4 at maximum load.
MPU150-3300, V3
All other models, V3
Full load, 20MHz bandwidth.
With 300 LFM forced air cooling. (Note 1)
Output voltage overshoot/undershoot at turn-on.
Varies by output. Total regulation includes: line changes over the specified.
input range, changes in load starting at 20% load and changing to 100% load.
Recovery time, to within 1% of initial set point due to a 50-100% load change,
5% max. deviation.
Time required for initial output voltage stabilization.
Time required for output voltage to rise from 10% to 90%.
MIN
NOM
MAX
65
75
4
3
N/A
0.3
See Model Selection Charts
150
0
See Model Selection Charts
500
2
20
UNITS
%
A
A
Watts
%
µS
Sec
mS
INTERFACE SIGNALS AND INTERNAL PROTECTION
PARAMETER
Overvoltage Protection
Overload Protection
Overtemperature Protection
Output Good
Input Power Fail Warning
Current Share
Remote Sense
Inhibit
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
Latch style overvoltage protection. Available on
2.5V output, V1 3.0
3.25
V1, V2, all models, and V3 on all models except
3.3V output, V1 4.1
4.65
MPU150-3300.
3.3V output, V2 3.8
4.2
5V output, V1, V2 6.0
6.4
12V output, V2 (Note 2) 14
16
MPU150-4350 3.3V output, V1 4.3
4.65
Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
System shutdown due to excessive internal temperature, automatic reset.
TTL compatible signal available for V1. Signal is high when
output is within 5% of nominal. Signal shall remain low for 20
milliseconds following loss of Output Good.
3.3V 3.16
5V 4.75
TTL compatible logic signal. Time before regulation dropout due to loss of input
5
power. May be used as independent PSOK signal in redundant applications.
Accuracy of shared current with up to 6 parallel units. Single wire current share
10
on V1 and V2 with return via -Sense return.
Available on V1 and V2. Total voltage compensation for cable losses with
500
respect to the main output.
Output voltage is inhibited by application of an external high (5V) signal.
NOTES: 1) Overvoltage range for 12V, V3 outputs: 14V to 19V.
UNITS
V
V
mS
%
mV
SAFETY, REGULATORY, AND EMI SPECIFICATIONS
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
Insulation Resistance
Leakage Current
Input to output.
Per EN60950.
NOTES: 1) This product is not rated for convection applications.
MIN
NOM
MAX
UNITS
Approved
MPU150 2600
MDU150 1544
B
B
8
10
±2
Line to Line 1
Line to Ground 2
10
MPU150 at 264 VAC
MDU150 at 72 VDC
1250
100
2) Overvoltage range for 12V, V3 outputs: 14V to 19V.
VDC
Class
kV
V/M
kV
kV
M
µA
3

Share Link: 