MPU150/MDU150 Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
Agency Approvals
Dielectric Withstand Voltage
Electromagnetic Interference
ESD Susceptibility
Radiated Susceptibility
EFT/Burst
Input Transient Protection
Insulation Resistance
Leakage Current
CONDITIONS/DESCRIPTION
UL1950.
CSA 22.2 NO. 234/950.
EN60950 (TÜV).
Input to output per EN60950.
MPU150
MDU150
FCC CFR title 47 Part 15 Sub-Part B - Conducted.
EN55022 / CISPR 22 Conducted.
Per EN61000-4-2, level 4.
Per EN61000-4-3, level 3.
Per EN61000-4-4, level 3.
Per EN61000-4-5, class 3.
MPU150:
MPU150:
MDU150:
MDU150:
Line to Line
Line to Ground
Line to Line
Line to Ground
Input to output.
Per EN60950.
Dual output MPU150 at 264 VAC
Single and triple output MPU150 at 264 VAC
MDU150 at 72 VDC
MIN
NOM
MAX
Approved
2600
1544
B
B
8
10
±2
1
2
0.5
0.5
10
22
1.7
(Not required by EN60950)
UNITS
VDC
Class
kV
V/M
kV
kV
M
mA
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
Operating.
Non-Operating.
Derate linearly above 50°C by 2.5% per °C.
0°C to 70°C (after 15 minute warm-up).
Non-Condensing.
Peak acceleration.
Random vibration, 10Hz to 2kHz, 3 axis.
MIN
At 100% load 0
At 50% load 0
-55
5
NOM
±0.02
MAX
10k
40k
50
70
85
±0.05
95
20
6
UNITS
ASL Ft.
ASL Ft.
°C
°C
°C
%/°C
%RH
GPK
GRMS
Options
DESCRIPTION
Metric Mounting
NOTES
Add “M” as a suffix to the model number to order chassis with
M4 x 0.7 mounting inserts. Metric mounting inserts are standard for
single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
SIZE IMPACT
8.00" x 4.20" x 1.50"
(203.2mm x 106.7mm x 38.1mm)
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date
manufactured. Specifications are subject to change without notice.
JUN 08, 2006 revised to JUL 14, 2006
Page 4 of 6
www.power-one.com