Pm25LV010/020/040
DEVICE OPERATION (CONTINUED)
READ DATA OPERATION
The Read Data (READ) instruction is used to read memory
data of Pm25LV010/020/040 under normal mode run-
ning up to 33 MHz.
The READ instruction is activated by pulling the CE#
line of the selected device to low (VIL), and the READ
instruction code is transmitted via the Sl line followed by
three bytes address (A23 - A0) to be read. There are
total 24 address bits will be shifted in, only the AMS (most-
significant address) - A0 will be decoded and the rest of
A23 - AMS can be don’t cared. Refer to Table 10 for the
related Address Key. Upon completion, any data on the
Sl will be ignored.
The first byte data D7 - D0 addressed (can be at any
location) is then shifted out onto the SO line. A single
byte data or up to whole memory array can be read out
in one READ instruction. The address is automatically
increamented to the next higher address after each byte
of data is shifted out. The read operation can be termi-
nated any time by driving the CE# high (VIH) after the
data comes out. When the highest address of the de-
vices is reached, the address counter will roll over to the
000000h address allowing the entire memory to be read
in one continuous READ instruction.
Table 10. Address Key
Address
AN
Don't Care Bits
Pm25LV010
A16 - A0
A23 - A17
Figure 11. Read Data Sequence
CE#
Pm25LV020
A17 - A0
A23 - A18
Pm25LV040
A18 - A0
A23 - A19
SCK
SI
SO
0 1 2 3 4 5 6 7 8 9 10 11 28 29 30 31 32 33 34 35 36 37 38 39
INSTRUCTION = 0000 0011b
3-BYTE ADDRESS
23 22 21 ... 3 2 1 0
HIGH IMPEDANCE
7 6 54 3 21 0
Programmable Microelectronics Corp.