DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADT7463 データシートの表示(PDF) - ON Semiconductor

部品番号
コンポーネント説明
メーカー
ADT7463 Datasheet PDF : 52 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
1
SCL
9
1
ADT7463
9
SDA
0
1
0
1
1
A1
A0 R/W
D7 D6 D5 D4 D3 D2 D1 D0
START BY
MASTER
FRAME 1
SERIAL BUS ADDRESS
BYTE
ACK. BY
ADT7463
FRAME 2
ADDRESS POINTER REGISTER BYTE
ACK. BY STOP BY
ADT7463 MASTER
Figure 8. Writing to the Address Pointer Register Only
1
9
1
9
SCL
SDA
0
1
START BY
MASTER
0
1
1
A1 A0 R/W
D7 D6 D5 D4 D3 D2 D1
FRAME 1
SERIAL BUS ADDRESS
BYTE
ACK. BY
ADT7463
FRAME 2
DATA BYTE FROM ADT7463
Figure 9. Reading Data from a Previously Selected Register
D0
NO ACK. BY STOP BY
MASTER MASTER
When reading data from a register, there are two possibilities:
1. If the ADT7463’s address pointer register value is unknown
or not the desired value, it is first necessary to set it to the
correct value before data can be read from the desired data
register. This is done by performing a write to the ADT7463
as before, however, only the data byte is sent and this con-
tains the register address. This is shown in Figure 8.
A read operation is then performed consisting of the serial
bus address, R/W bit set to 1, followed by the data byte read
from the data register. This is shown in Figure 9.
2. If the address pointer register is already at the desired address,
data can be read from the corresponding data register without
first writing to the address pointer register, so Figure 8 can
be omitted.
Notes
1. It is possible to read a data byte from a data register without
first writing to the address pointer register if the address
pointer register is already at the correct value. However, it is
not possible to write data to a register without writing to the
address pointer register because the first data byte of a write
is always written to the address pointer register.
2. In Figures 7 to 9, the serial bus address is shown as the
default value 01011(A1)(A0), where A1 and A0 are set by
the address select mode function previously defined.
3. In addition to supporting the Send Byte and Receive Byte
protocols, the ADT7463 also supports the Read Byte protocol
(see System Management Bus specifications Rev. 2.0 for
more information).
4. If it is required to perform several read or write operations in
succession, the master can send a repeat start condition
instead of a stop condition to begin a new operation.
REV. C
Rev. 4 | Page 11 of 52 | www.onsemi.com