NX25F080A
Table 3. Command Set for the NX25F080A Serial Flash Memory
Command Name
Byte 0 Byte 1-2 Byte 3-4
n-bytes
(italics indicate device output)
1
Serial Flash Sector Commands
Read from Sector
Read from Sector Low Frequency
Write Enable*
Write Disable*
Write to Sector
Transfer SRAM to Sector
Transfer Sector to SRAM
Compare Sector with SRAM
52H sector addr. byte add. 0000H ready/busy
51H sector addr. byte add. 0000H ready/busy
06H
00H
04H
00H
F3H sector addr. byte add.
write data
F3H sector addr. 0000H
54H sector addr. byte add.
clock 00H per byte
86H sector addr. byte add. 0000H ready/busy
read data
read data
2
00H
3
00H
bit compare of data
4
Serial SRAM Program Buffer Commands
Write to SRAM**
Read from SRAM*
82H
0000H
byte add.
write data
00H
5
81H
0000H
byte add. 0000H
read/busy
read data
Transfer SRAM to Prog. Buffer
92H
0000H
0000H 0000H
Transfer Prog. Buffer to SRAM
Read from Program Buffer
55H
0000H
0000H 0000H
91H
0000H
byte add. 0000H ready/busy
read data
6
Configuration and Status Commands
Read Configuration Register*
8BH
0000H
0000H 0000H ready/busy configuration
7
Write Configuration Register
8AH configuration 0000H
Read Status Register*
83H
0000H
0000H 0000H ready/busy
status
Clear Compare Status*
Read Device Information Sector
89H
0000H
15H
0000H
0000H
0000H
ready/busy
8
read data
Notes:
1. * Command may be used when device is busy
9
2. ** Command may not be used when device is busy and TR bit=0
SERIAL FLASH MEMORY COMMANDS:
Read from Sector
Reading from a sector is accomplished by first bringing CS
low then shifting in the Read from Sector command (52H)
followed by its 16-bit sector-addressfield. Although the
sector-address field is 16-bits, only bits S[10:0] for the
NX25F080A (0-7FFH) are used. The uppermost sector
address bits are not used but must be clocked using 0
10
11
for data. Next a 16-bit byte-addressfield is clocked
into the device to designate the starting location within
the 536-byte sector. Only B[9:0] of the byte-address field
12 are used; the uppermost bits are not used but must be
clocked in (use 0 for data). Only byte-addresses of 0 to
217H (536 bytes) are valid.