2-Wire Serial 8-Bit DACs with
Rail-to-Rail Outputs
Furthermore if the transmission’s last command byte
has PD high, the output latches are updated, but volt-
age outputs will not reflect the newly entered data
because the DAC enters power-down mode when the
STOP condition is detected. When in power-down, the
DAC outputs float. In this mode, the supply current is a
maximum of 20µA. A command byte with the PD bit low
returns the MAX517/MAX518/MAX519 to normal opera-
tion following a STOP condition, with the voltage out-
puts reflecting the output-latch contents (Figures 10a
and 10b). Because each subsequent command byte
overwrites the previous PD bit, only the last command
byte of a transmission affects the power-down state.
Setting the RST bit high clears the DAC input latches.
The DAC outputs remain unchanged until a STOP con-
dition is detected (Figure 11a). If a reset is issued, the
following output byte is ignored. Subsequent pairs of
command/output bytes overwrite the input latches
(Figure 11b).
All changes made during a transmission affect the
MAX517/MAX518/MAX519’s outputs only when the
transmission ends and a STOP has been recognized.
The R0, R1, and R2 bits are reserved and must be set
to zero.
I2C Compatibility
The MAX517/MAX518/MAX519 are fully compatible
with existing I2C systems. SCL and SDA are high-
impedance inputs; SDA has an open drain that pulls
the data line low during the 9th clock pulse. Figure 12
shows a typical I2C application.
11
(a)
or or
(PD)
0 1 0 AD3 AD2 AD1 AD0 0 0 0 0 0 0 0
0
SDA
XXX
START
CONDITION
ADDRESS BYTE
ACK
COMMAND BYTE
ACK
( ) STOP DEVICE RETURNS TO
CONDITION NORMAL OPERATION
11
(b)
or or
(PD)
0 1 0 AD3 AD2AD1 AD0 0 0 0 0 0 0 0
00 00000000 0
SDA
XX
START
CONDITION
ADDRESS BYTE
NOTE: X = DON'T CARE
ACK
COMMAND BYTE
ACK
(ADDRESSING DAC0)
OUTPUT BYTE
ACK
(SET TO 0)
STOP
DAC0 INPUT
CONDITION
( ) LATCH SET TO 0. DEVICE RETURNS TO NORMAL OPERATION.
( ) DAC0 SET TO 0.
Figure 10. Returning to Normal Operation from Power-Down
11
(a)
or or
(RST)
0 1 0 AD3 AD2 AD1AD0 0 0 0 0 0 1 0
0
SDA
XXX
ADDRESS BYTE
ACK
COMMAND BYTE
ACK
START
STOP
CONDITION
(b)
11
or or
ALL INPUT LATCHES CONDITION
( ) SET TO 0.
ALL OUTPUTS
( ) (RST)
SET TO 0.
0 1 0 AD3 AD2 AD1 AD0 0 0 0 0 0 1 0
0
0
SDA
XXX XXXXXXXX
START
CONDITION
ADDRESS BYTE
NOTE: X = DON'T CARE
ACK
COMMAND BYTE
ACK
"DUMMY"
OUTPUT BYTE
( ) ALL INPUT LATCHES
SET TO 0.
ACK ADDITIONAL
COMMAND BYTE/
OUTPUT BYTE PAIRS
STOP
CONDITION
( ) DAC OUTPUTS SET TO 0 UNLESS
CHANGED BY ADDITIONAL COMMAND
BYTE/OUTPUT BYTE PAIRS.
Figure 11. Resetting DAC Outputs