Table 6. AC Characteristics the 87C196CA/87C196CB - Express Meets (Sheet 2 of 2)
Symbol
Parameter
Min
Max
Units
RD Low to CLKOUT Low
TRLCL
CA
+4
CB
–8
+ 30
ns
+ 20
TRLRH
RD# Low Period
TOSC–10
ns (5)
TRHLH
TRLAZ
TLLWL
TCLWL
TQVWH
TCHWH
RD# High to ALE/ADV# High
RD# Low to Address Float
ALE/ADV# Low to WR# Low
CLKOUT Low to WR# Low
Data Valid before WR# High
CLKOUT High to WR# High
TOSC
TOSC–10
–5
TOSC–23
–10
TOSC+25
5
+ 25
+ 15
ns (3)
ns
ns
ns
ns
ns
TWLWH
WR# Low Period
CA
TOSC–30
CB
TOSC–20
ns (5)
TWHQX
TWHLH
TWHBX
TWHAX
Data Hold after WR# High
WR# High to ALE/ADV# High
BHE#, INST Hold after WR# High
AD8-15 Hold after WR# High
TOSC–25
TOSC–10
TOSC–10
TOSC–30
TOSC+15
ns
ns (3)
ns
ns (4)
TRHBX
BHE#, INST Hold after RD# High
TOSC–10
ns
TRHAX
AD8-15 Hold after RD# High
TOSC–30
ns (4)
NOTES:
1. Testing performed at 4 MHz, however, the device is static by design and typically operates below 1 Hz.
2. Typical specifications, not guaranteed.
3. Assuming back-to-back bus cycles.
4. 8-bit bus only.
5. If wait states are used, add 2TOSC x n = number of wait states. If mode 0 (1 automatic wait state added)
operation is selected, add 2TOSC to specification.
6. TOFD is the time for the oscillator fail detect circuit (OFD) to react to a clock failure. The OFD circuitry is
enabled by programming the UPROM location 0778H with the value 0004H. Programming the CDE bit
enables oscillator fail detection.
ADVANCE INFORMATION Datasheet