Data Sheet
XE1203
Here are examples of LO frequency settings in FSParam_Freq when mode 2 is used.
Byte Address
01010
Bit 7
Bit 0
Byte Address
01011
Bit 7
Bit 0
00000000
00000000
00000000
00000000
11111111
11111111
00000001
00000010
11111111
11111110
Resulting LO setting
Note: reference frequency = 39.0 MHz
F0, where F0 depends on the selected frequency
band (see FSParam_Band )
F0 = 434.0 MHz for the 433-435 MHz band
F0 = 869.0 MHz for the 868-870 MHz band
F0 = 915.0 MHz for the 902-928 MHz band
F0 + 500 Hz
F0 + 2 * 500 Hz
F0 – 500 Hz
F0 – 2 * 500 Hz
5.2.5 DataOut register
The detailed description of the “DataOut” register is given in the next table.
Name
DataOut_Rssi
Reserved
DataOut_MSB_fei
DataOut_LSB_fei
Bits Address
Description
7-6
01100 RSSI output:
0 0 -> lowest level
0 1 -> 2nd level
1 0 -> 3rd level
1 1 -> highest level
5-4
01100 Set to zero
3-0
01100 Fei output (MSB)
7-0
01101 Fei output (LSB)
Ferror = (Br/8)*int(DataOut_MSB_fei & DataOut_LSB_fei)
Where int(x) = integer value of the binary representation of x.
26