PRELIMINARY
Absolute Maximum Ratings
Operating Conditions
Power Supply Voltage
Power Supply Voltage
VDD
-0.3V to +4.2V
VDD
VPP
-0.3V to +4.2V VPP
Voltage on Any Pin
with GND = 0V (VI)
Storage Temperature Range (TS)
Lead Temperature (solder 4 sec.) (TL)
-0.3V to +4.2V
-65°C to +150°C
260°C
Operating Temperature(TA)
Thermal Resistance(Typical) θJA (°C/W)
TSSOP Package
130°C
2.7V to 3.6V
VDD to 3.6V
-40°C to 85°C
CAUTION: Stress above those listed in “Absolute Maximum Ratings” may cause permanent damage to the device. Other conditions
above those indicated in the operational sections of this specification are not implied.
Electrical Characteristics VDD = 3.0V, -40°C < TA < 85°C, Except as Specified
Symbol
Parameter
Conditions
Min
Typ
Max
IDD
IDD-PWDN
fINRF
fINIF
fOSC
fΦ
PfINRF
PfINIF
VOSC
VIH
VIL
IIH
IIL
IIH
IIL
VOH
VOL
t CS
t CH
t CWH
t CWL
t ES
t EW
Power Supply Current
Powerdown Current
Operating Frequency
RF
VDD=2.7V to 3.6V,
fΦ= 10KHz
IF
VDD=2.7V to 3.6V,
fΦ= 10KHz
VDD=3.0V
3.2
5.4
1.2
1
10
0.5
-
2.0
Operating Frequency
50
-
500
Oscillator Frequency.
4
-
40
Maximum Phase Detector Freq.
10
-
-
RF Input Sensitivity
IF Input Sensitivity
Oscillator Sensitivity
High Level Input Voltage
Low Level Input Voltage
High Level Input Current
Low Level Input Current
Oscillator Input Current
Oscillator Input Current
High-Level Output Voltage
Low-Level Output Voltage
Data Clock Setup Time
VDD=2.7V to 3.6V
- 8.5
-
0
VDD=2.7V to 3.6V
-10
-
0
OSCIN
0.5
-
-
*
0.8 VDD
-
-
*
-
-
0.2 VDD
VIH =VDD=3.6V*
-1.0
-
1.0
VIL =0V, VDD=3.6V*
-1.0
-
1.0
VIH =VDD=3.6V
-
-
100
VIL =0V, VDD=3.6V
-100
-
-
IOH = -500 µA
VDD-0.4
-
-
IOL = 500 µA
-
-
0.4
See Data Input Timing
50
-
-
Data Clock Hold Time
See Data Input Timing
10
-

Clock Pulse Width High
See Data Input Timing
50
-
-
Clock Pulse Width Low
See Data Input Timing
50
-
-
Clock to Load Enable Setup Time See Data Input Timing
50
-
-
Load Enable Pulse Width
See Data Input Timing
50
-
-
* Clock, Data and LE. Does not include fINRF, fINIF and OSCIN.
Units
mA
mA
µA
GHz
MHz
MHz
MHz
dBm
dBm
VPP
V
V
µA
µA
µA
µA
V
V
ns