ADuM1400/ADuM1401/ADuM1402
DIN EN 60747-5-2 (VDE 0884 PART 2) INSULATION CHARACTERISTICS
Table 7.
Description
Installation Classification per DIN VDE 0110
For Rated Mains Voltage ≤ 150 V rms
For Rated Mains Voltage ≤ 300 V rms
For Rated Mains Voltage ≤ 400 V rms
Climatic Classification
Pollution Degree (DIN VDE 0110, Table 1)
Maximum Working Insulation Voltage
Input to Output Test Voltage, Method b1
VIORM × 1.875 = VPR, 100% Production Test, tm = 1 sec, Partial Discharge < 5 pC
Input to Output Test Voltage, Method a
After Environmental Tests Subgroup 1
VIORM × 1.6 = VPR, tm = 60 sec, Partial Discharge < 5 pC
After Input and/or Safety Test Subgroup 2/3
VIORM × 1.2 = VPR, tm = 60 sec, Partial Discharge < 5 pC
Highest Allowable Overvoltage (Transient Overvoltage, tTR = 10 sec)
Safety-Limiting Values (Maximum value allowed in the event of a failure; also see
Thermal Derating Curve, Figure 4)
Case Temperature
Side 1 Current
Side 2 Current
Insulation Resistance at TS, VIO = 500 V
Symbol
VIORM
VPR
VPR
VTR
TS
IS1
IS2
RS
Characteristic
I–IV
I–III
I–II
40/105/21
2
560
1050
896
672
4000
150
265
335
>109
Unit
V peak
V peak
V peak
V peak
V peak
°C
mA
mA
This isolator is suitable for basic electrical isolation only within the safety limit data. Maintenance of the safety data is ensured by protec-
tive circuits.
The * marking on packages denotes DIN EN 60747-5-2 approval for 560 V peak working voltage.
350
300
250
SIDE #2
200
150
SIDE #1
100
50
0
0
50
100
150
200
CASE TEMPERATURE (°C)
Figure 4. Thermal Derating Curve, Dependence of Safety Limiting Values
with Case Temperature per DIN EN 60747-5-2
RECOMMENDED OPERATING CONDITIONS
Table 8.
Parameter
Operating Temperature
Supply Voltages1
Input Signal Rise and Fall Times
Symbol Min Max Unit
TA
–40 +105 °C
VDD1, VDD 2 2.7 5.5 V
1.0 ms
1 All voltages are relative to their respective ground.
See the DC Correctness and Magnetic Field Immunity section on Page 19 for
information on immunity to external magnetic fields.
Rev. B | Page 13 of 24