DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADUM1400(2004) データシートの表示(PDF) - Analog Devices

部品番号
コンポーネント説明
メーカー
ADUM1400
(Rev.:2004)
ADI
Analog Devices ADI
ADUM1400 Datasheet PDF : 24 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ADuM1400/ADuM1401/ADuM1402
Table 12. ADuM1401 Pin Function Descriptions
Pin
No. Mnemonic Function
1 VDD1
Supply Voltage for Isolator Side 1, 2.7 V to 5.5 V.
2 GND1
Ground 1. Ground reference for isolator Side 1.
3 VIA
Logic Input A.
4 VIB
Logic Input B.
5 VIC
Logic Input C.
6 VOD
Logic Output D.
7 VE1
Output Enable 1. Active high logic input. VOD output is enabled when VE1 is high or disconnected. VOD is disabled when VE1 is low. In
noisy environments, connecting VE1 to an external logic high or low is recommended.
8 GND1
Ground 1. Ground reference for isolator Side 1.
9 GND2
Ground 2. Ground reference for isolator Side 2.
10 VE2
Output Enable 2. Active high logic input. VOA, VOB, and VOC outputs are enabled when VE2 is high or disconnected. VOA, VOB, and VOC
outputs are disabled when VE2 is low. In noisy environments, connecting VE2 to an external logic high or low is recommended.
11 VID
Logic Input D.
12 VOC
Logic Output C.
13 VOB
Logic Output B.
14 VOA
Logic Output A.
15 GND2
Ground 2. Ground reference for isolator Side 2.
16 VDD2
Supply Voltage for Isolator Side 1, 2.7 V to 5.5 V.
Table 13. ADuM1402 Pin Function Descriptions
Pin
No. Mnemonic Function
1 VDD1
Supply Voltage for Isolator Side 1, 2.7 V to 5.5 V.
2 GND1
Ground 1. Ground reference for isolator Side 1.
3 VIA
Logic Input A.
4 VIB
Logic Input B.
5 VOC
Logic Output C.
6 VOD
Logic Output D.
7 VE1
Output Enable 1. Active high logic input. VOC and VOD outputs are enabled when VE1 is high or disconnected. VOC and VOD outputs are
disabled when VE1 is low. In noisy environments, connecting VE1 to an external logic high or low is recommended.
8 GND1
Ground 1. Ground reference for isolator Side 1.
9 GND2
Ground 2. Ground reference for isolator Side 2.
10 VE2
Output Enable 2. Active high logic input. VOA and VOB outputs are enabled when VE2 is high or disconnected. VOA and VOB outputs are
disabled when VE2 is low. In noisy environments, connecting VE2 to an external logic high or low is recommended.
11 VID
Logic Input D.
12 VIC
Logic Input C.
13 VOB
Logic Output B.
14 VOA
Logic Output A.
15 GND2
Ground 2. Ground Reference for Isolator Side 2.
16 VDD2
Supply Voltage for Isolator Side 2, 2.7 V to 5.5 V.
Rev. B | Page 16 of 24