LinkSwitch-HP
Parameter
Symbol
Multi-Function (PD) Input
PROGRAM/DELAY
Pin Voltage
VPD
PROGRAM/DELAY
Pin Time Lower
Voltage Threshold
VPD(DL)
PROGRAM/DELAY
Pin Time Upper
Voltage Threshold
VPD(DU)
Fast AC Reset
Threshold
VPDTHACR
Remote On/Off
Threshold
VPDTHRM
Remote On/Off Delay
Circuit Protection
Self Protection
Current Limit
ILIMIT
Programmed Current
Limit Variation
Operational Peak
Current Variation
Thermal Shutdown
Temperature
Thermal Shutdown
Hysteresis
Leading Edge
Blanking Time
Current Limit
Delay Time
Minimum Switch
ON-Time
ΔILIMIT
ΔIPK(OP)
TSD
TSDH
tLEB
tILD
TON(MIN)
Conditions
SOURCE = 0 V; TJ = -40 to 125 °C
Min
Typ
Max
Units
(Unless Otherwise Specified)
TJ = +25 °C
TJ = +25 °C
1.20
1.25
1.30
V
0.50
0.535
0.57
V
TJ = +25 °C
1.20
1.25
1.30
V
TJ = +25 °C
Threshold
Hysteresis
TJ = +25 °C
3.06
3.4
3.74
V
1.25
1.35
1.45
V
0.8
8
Switching
Cycles
LNK6xx3
di/dt = 180 mA/ms
TJ = +25 °C
0.716
0.77
0.824
LNK6xx4
di/dt = 245 mA/ms
TJ = +25 °C
0.967
1.04
1.113
LNK6xx5
di/dt = 305 mA/ms
TJ = +25 °C
1.209
1.30
1.391
A
LNK6xx6
di/dt = 460 mA/ms
TJ = +25 °C
1.814
1.95
2.087
LNK6xx7
di/dt = 610 mA/ms
TJ = +25 °C
2.418
2.60
2.782
See Table 3 for programming
0 °C ≤ TJ ≤ +100 °C, See Note A
±7
%
IPK(OP) = 25 -100% × ILIMIT,
0 °C ≤ TJ ≤ +100 °C, See Note A
±7
%
135
142
150
°C
CBP = 0.47 μF or CBP = 4.7 μF
TJ = +25 °C
See Note A
TJ = +25 °C
t + t LEB(MAX) ILD(MAX)
TJ = +25 °C
75
°C
175
220
ns
100
ns
325
400
500
ns
www.powerint.com
15
Rev. C 03/14