DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

2760A25 データシートの表示(PDF) - Maxim Integrated

部品番号
コンポーネント説明
メーカー
2760A25
MaximIC
Maxim Integrated MaximIC
2760A25 Datasheet PDF : 25 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
DS2760
Summary. All of the protection conditions described above are OR’ed together to affect the CC and DC
outputs.
DC = (Undervoltage) or (Overcurrent, EITHER Direction) or (Short Circuit) or
(Protection Register bit DE = 0) or (Sleep Mode)
CC = (Overvoltage) or (Undervoltage) or (Overcurrent, Charge Direction) or (Protection Register
bit CE = 0) or (Sleep Mode)
CURRENT MEASUREMENT
In the Active Mode of operation, the DS2760 continually measures the current flow into and out of the
battery by measuring the voltage drop across a current sense resistor. The DS2760 is available in two
configurations: (1) internal 25mW current sense resistor, and (2) external user-selectable sense resistor. In
either configuration, the DS2760 considers the voltage difference between pins IS1 and IS2 (VIS = VIS1
VIS2) to be the filtered voltage drop across the sense resistor. A positive VIS value indicates current is
flowing into the battery (charging), while a negative VIS value indicates current is flowing out of the
battery (discharging).
VIS is measured with a signed resolution of 12-bits. The current register is updated in two’s complement
format every 88ms (128/fsample) with an average of 128 readings. Currents outside the range of the
register are reported at the limit of the range. The format of the Current Register is shown in Figure 4.
For the internal sense resistor configuration, the DS2760 maintains the Current Register in units of Amps,
with a resolution of 0.625mA and full scale range of no less than ±1.9A (see Note 7 on IFS spec for more
details). The DS2760 automatically compensates for internal sense resistor process variations and
temperature effects when reporting current.
For the external sense resistor configuration, the DS2760 writes the measured VIS voltage to the Current
Register, with a resolution of 15.625mV and a full scale range of ±64mV.
CURRENT REGISTER FORMAT Figure 4
MSB—Address 0E
S 211 210 29 28 27 26 25
MSb
LSb
LSb—Address 0F
24 23 22 21 20 X X X
MSb
LSb
Units: 0.625 mA for internal sense resistor
15.625 mV for external sense resistor
CURRENT ACCUMULATOR
The Current Accumulator facilitates remaining capacity estimation by tracking the net current flow into
and out of the battery. Current flow into the battery increments the Current Accumulator while current
flow out of the battery decrements it. Data is maintained in the Current Accumulator in two’s-
complement format. The format of the Current Accumulator is shown in Figure 5.
When the internal sense resistor is used, the DS2760 maintains the Current Accumulator in units of Amp-
hours, with a resolution of 0.25mAhrs and full scale range of ±8.2Ahrs. When using an external sense
8