Chart-2 Vertical Direction Timing Chart
MODE
Draft mode
Applicable CCD image sensor
• ICX412
VD
HD
SUB
V1A
V1B
V2
V3A
V3B
V4
CCD OUT
PBLK
CLPOB
Wide CLPOB
CLPDM
ID/EXP
WEN
260
287 1 2
D
6 3 10 15 22 27 30
4 1 8 13 20 25 28
260
287 1 2
D
6 3 10 15 22 27 30
4 1 8 13 20 25 28
∗ The number of SUB pulses is determined by the serial interface data. This chart shows the case where SUB pulses are output in each horizontal period.
∗ ID/EXP of this chart shows ID. ID is low for lines where CCD OUT contains the R component, and high for lines where CCD OUT contains the B component.
∗ VD of this chart is NTSC equivalent pattern (285H + 1455ck + 1455ck units). For PAL equivalent pattern, it is 342H + 2592ck units.