EEPROM-Programmable, Hex/Quad,
Power-Supply Sequencers/Supervisors
when that output is logic-high. No output can depend
solely on MR.
The positive voltage monitors generate fault signals
(logical 0) to the MAX6872/MAX6873s’ logic array when
an input voltage is below the programmed undervolt-
age threshold, or when that voltage is above the over-
voltage threshold. The negative voltage monitor (IN2)
generates a fault signal to the logic array when the
input voltage is less negative than the undervoltage
threshold, or when that voltage is more negative than
the overvoltage threshold.
Registers 0Eh through 3Ah and 40h configure each of
the programmable outputs. Programmable timing
blocks set the PO_ timeout period from 25µs to 1600ms
Table 7. Programmable Output Behavior and MARGIN
REGISTER
ADDRESS
EEPROM
MEMORY
ADDRESS
BIT
RANGE
[0]
[1]
[2]
[3]
41h
8041h
[4]
[5]
[6]
[7]
[0]
[1]
[2]
[3]
42h
8042h
[4]
[5]
[6]
[7]
AFFECTED OUTPUT
DESCRIPTION
PO1
(MAX6872 only)
PO2
(MAX6872 only)
PO3 (MAX6872)
PO1 (MAX6873)
PO4 (MAX6872)
PO2 (MAX6873)
PO5 (MAX6872)
PO3 (MAX6873)
PO6 (MAX6872)
PO4 (MAX6873)
PO7 (MAX6872)
PO5 (MAX6873)
PO8
(MAX6872 only)
PO1
(MAX6872 only)
PO2
(MAX6872 only)
PO3 (MAX6872)
PO1 (MAX6873)
PO4 (MAX6872)
PO2 (MAX6873)
PO5 (MAX6872)
PO3 (MAX6873)
PO6 (MAX6872)
PO4 (MAX6873)
PO7 (MAX6872)
PO5 (MAX6873)
PO8
(MAX6872 only)
0 = output held in existing state.
1 = output asserts high or low (see 42h[0]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[1]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[2]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[3]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[4]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[5]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[6]).
0 = output held in existing state.
1 = output asserts high or low (see 42h[7]).
0 = output asserts low if 41h[0] = 1.
1 = output asserts high if 41h[0] = 1.
0 = output asserts low if 41h[1] = 1.
1 = output asserts high if 41h[1] = 1.
0 = output asserts low if 41h[2] = 1.
1 = output asserts high if 41h[2] = 1.
0 = output asserts low if 41h[3] = 1.
1 = output asserts high if 41h[3] = 1.
0 = output asserts low if 41h[4] = 1.
1 = output asserts high if 41h[4] = 1.
0 = output asserts low if 41h[5] = 1.
1 = output asserts high if 41h[5] = 1.
0 = output asserts low if 41h[6] = 1.
1 = output asserts high if 41h[6] = 1.
0 = output asserts low if 41h[7] = 1.
1 = output asserts high if 41h[7] = 1.
______________________________________________________________________________________ 17